(another web site with products by Paul Wilton) |
Burner Nozzle Specifications and Installation Instructions is on this page! |
Prices and Ordering Info | Contact Information | ||
| Back to Intro Page | |||||
| Wilton Technologies |
![]() |
burner nozzles
|
for glass furnaces
and glory holes |
|
|
|
||||
|
Dimensions of the Wilton Flame Retaining
Ceramic Burner Nozzles
|
||||||
![]() |
Catalog Number | Pipe Size (A) | Overall Length (B) | Ceramic Length (C) | Ceramic Diameter (D) | Net Weight |
|
#1000 F |
1.50" | 5.50" | 2.50" | 3.50" | 5 Lbs. | |
|
#1000 G |
1.50" | 5.50" | 2.50" | 3.50" | 5 Lbs. | |
|
#1500 F |
1.50" | 5.50" | 2.50" | 4.00" | 6 Lbs. | |
|
#1500 G |
1.50" | 5.50" | 2.50" | 4.00" | 6 Lbs. | |
|
#2000 F |
2.00" | 5.75" | 3.00" | 5.00" | 8 Lbs. | |
|
#2000 G |
2.00" | 5.75" | 3.00" | 5.00" | 8 Lbs. | |
|
Capacity Table for the Wilton Flame
Retaining Ceramic Burner Nozzles
|
||||
|
1000 BTU / Hour at Various Mixture Pressures (Inches
W.C. )
|
||||
| Catalog Number | Pipe Size (A) |
3"
|
6"
|
9"
|
|
#1000 F |
1.50" |
105
|
160
|
200
|
|
#1000 G |
1.50" |
150
|
225
|
280
|
|
#1500 F |
1.50" |
200
|
300
|
375
|
|
#1500 G |
1.50" |
270
|
380
|
480
|
|
#2000 F |
2.00" |
360
|
515
|
630
|
|
#2000 G |
2.00" |
450
|
630
|
800
|
|
Figures are approximations based on 80% combustion
air as primary.
|
||||
|
Recommended Uses for the Wilton Flame
Retaining Ceramic Burner Nozzles
|
||
|
#1000 F |
for Small Furnaces | up to 30 Pounds of Glass |
|
#1000 G |
for Small Glory Holes | 5 Gallon Bucket |
|
#1500 F |
for Medium Furnaces | 30 to 300 Pounds of Glass |
|
#1500 G |
for Medium Glory Holes | 35 Gallon Drum |
|
#2000 F |
for Large Furnaces | Consult Manufacturer |
|
#2000 G |
for Large Glory Holes | 55 Gallon Drum |
|
Installation Instructions
|
||
|
Wilton Flame Retaining Ceramic Burner
Nozzles
|
||
![]() |
1.
|
Burner port should be a minimum of 2" bigger than the burner nozzle. |
|
2.
|
Refer to Figure "A" to the left. Install burner nozzle, maintaining 1" clearance all around. | |
|
3.
|
Insert burner nozzle 1" into combustion chamber and seal with 2600 degree fiber frax. | |
|
4.
|
If furnace installation is used, paint inside surface of fiber frax with green patch #421 or equivalent. | |
|
5.
|
If glory hole installation is used, paint inside surface of fiber frax with ins-tuff rigidizer or equivalent. | |
| Caution: | Operation of combustion equipment can be hazardous resulting in bodily injury or equipment damage. Each burner should be supervised by a combustion safeguard, and only qualified personnel should install, make system adjustments and perform any required services | |
Select from
Large
Medium
and Small.